ASSIST-QuickSearch Document Details
Title: Chemical Passivation Treatments for Stainless Steel Parts (Replaced by ASTM-A967/A967M) Scope: This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless steel parts. Status:
A967 Standard Specification for Chemical
Scope. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and …
Citric Acid Passivation of 15-5PH and 17-4PH Stainless Steel …
Materials used in this investigation were SS 304, 15-5PH, and 17-4PH whose chemical composition was determined by X-ray fluorescence. Preparation of the electrodes: each of the SS was prepared according to ASTM A380 [] in order to obtain a surface without harshness, after which a washing and rinsing was carried out to eliminate preparation …
Chemical Passivation Treatments for Stainless Steel Parts
A 967 2 3. Terminology 3.1 Definition of Term Specific to This Standard—It is necessary to define which of the several commonly used definitions of the term passivation will be used in this specification.(See Discussion.) 3.1.1 Discussion—Stainless steels are autopassivating in the sense that the protective passive film is formed spontaneously
Passivation · ASTM A 967-05 SPECIFICATIONS
Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU.
2017 CSID Usoa Izagirre TECNALIA Christopher …
Salt Spray test (ASTM B117) Passivation effectiveness assessment as per ASTM A967 and AMS2700C 48 hours of exposure (2 hours are required as minimum in the ASTM A967/A967M-13 standard) 2 hours of exposure for AISI 440C and Cronidur30 (very sensitive to corrosion) The rust or staining after completion of the test shall
ASTM A967/A967M-17
Full Description. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations …
Equivalent to QQ-P-35 spec for passivation of stainless steel? ASTM A967?
The ASTM replacement for QQ-P-35, A967, renumbers these to Nitric 1, 2, 3, and 4. SAE's replacement for QQ-P-35, AMS2700 [affil link], brought back all the removed baths and lists them as Method 1, Type 1-8. ASTM A967 [affil link] also has a Citric section, and AMS 2700 has citric as Method 2. Officially, only DoD users are compelled to the ...
Passivation of Stainless Steel | ASTM A967, AMS 2700
Passivation of Stainless Steel to ASTM A967. Five nitric and citric methods are listed as follows: Nitric 1: 20-25 v% Nitric Acid, 2.5 w% Sodium Dichromate, 120-130F, 20 Mins minimum. Nitric 2: 20-45 v% Nitric Acid, 70-90F, 30 Mins minimum. Nitric 3: 20-25 v% Nitric Acid, 120-140F, 20 Mins minimum.
Unpacking ASTM A967
ASTM A967 defines seven tests for verification that a suitable passive surface has been formed on the component surface. These tests are all qualitative. Although some tests can more precisely detect the amount of free iron remaining on a surface, they are meant to serve as a go, no-go test for passivation. Water immersion test.
ASTM A 380/A380M : 2017 | Stainless Steel Cleaning | SAI …
Fastener Part Standard - Hexagon Socket, Square Head, and Slotted Headless Set Screws - Inch Dimensioned. AWWA C220 : 2017. STAINLESS-STEEL PIPE, 1/2 IN. (13 MM) AND LARGER. ASTM A 781/A781M : 2018-02. SPECIFICATION FOR CASTINGS, STEEL AND ALLOY, COMMON REQUIREMENTS, FOR GENERAL …
A967/A967M Standard Specification for Chemical
AbstractThis specification covers several different types of chemical passivation treatments for stainless steel parts. The treatments are the following: immersion treatment using nitric acid solutions, immersion treatment using citric acid solution, and
Chemical Passivation Treatments for Stainless Steel Parts …
A967/A967M − 13 of free iron from the stainless steel surface would be an 14.1.2 The sample representing the lot of passivated parts aqueous solution of sodium dichromate. ... ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this ...
Revision of A967/A967M-17 Standard Specification for …
A967 was developed for replacement of Mil QQ-P 35. As part of the development, the word "dissolved" appears to be accidental dropped in para. 7.2. for the description of clean water. ... ASTM offers descriptions of work items in the interest of openness, as well as to solicit input from interested stakeholders who may not be …
A380/A380M Standard Practice for Cleaning
1.1 This practice covers recommendations and precautions for cleaning, descaling, and passivating of new stainless steel parts, assemblies, equipment, and installed systems. These recommendations are presented as procedures for guidance when it is recognized that for a particular service it is desired to remove surface contaminants that …
WK77171 Revision of A967/A967M-17 Standard
Revision of A967/A967M-17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Rationale. ... ASTM Standard C33, 2003e1, "Specification for Concrete Aggregates," ASTM International, West Conshohocken, PA, 2003, DOI: 10.1520/C0033 ...
a967
PDF Price. $76.00. 0 Add to cart. As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its …
Standard Test Method for Compressive Strength of …
Scope. 1.1 This test method covers determination of compressive strength of cylindrical concrete specimens such as molded cylinders and drilled cores. It is limited to concrete having a density in excess of 800 kg/m 3 [50 lb/ft 3 ]. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard.
プロセス | Vaisala
は、ASTM A967やASTM F86–13などのさまざまなにってわれます。. その、とにするがく、およびでのにながられます。. アプリケーションノートをダウンロードし、ヴァイサラ K ...
ASTM A967/A967M-13
1.6 The following precautionary caveat pertains only to the test method portions, Section 14 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory …
Standard Guide for Descaling and Cleaning Titanium
Scope. 1.1 This guide covers a cleaning and descaling procedure useful to producers, users, and fabricators of titanium and titanium alloys for the removal of ordinary shop soils, oxides, and scales resulting from heat treatment operations and foreign substances present as surface contaminants. 1.2 It is not intended that these procedures …
ASTM A967 : Standard Specification for Chemical …
ASTM A967, 2005 Edition, September 1, 2005 - Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless …
ASTM A967/A967M-17
ASTM International [astm] PDF Price. $57.00. Add to cart Not a Member? Find out how to get ANSI Member Discount Others Also Bought. ASTM A380/A380M-17. Standard Practice for Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment, and Systems ... ASTM A967/A967M-13; Included in Packages.
Passivation Basics | Products Finishing
For many types of parts and industries, including many military specifications, ASTM standards A380 and A967 (astm.org) provide the guidelines for good passivation practice. These standards detail acceptable methods and/or recipes for passivating stainless steel and provide tests for measuring passivation success. AMS2700C (sae.org) …
A967 Standard Specification for Chemical
Scope. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless steel parts. It includes several alternative tests, with acceptance criteria, for confirmation of effectiveness of …
ステンレススチール
astm a380 astm a967 (1、2、5) qq-p-35 (タイプ ii & vi) rohs、reach、elvおよびweee の の サイズ 132インチ x 48インチ x 28インチ 20" x 30" x 9"---
Revision of A967/A967M-17 Standard Specification for …
Revision of A967/A967M-17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Rationale. ... ASTM Standard C33, 2003e1, "Specification for Concrete Aggregates," ASTM International, West Conshohocken, PA, 2003, DOI: 10.1520/C0033 ...
Passivation of Corrosion Resistant Steels
AMS 2700 has no guidelines for descaling or chemical cleaning processes detailed in ASTM A380 and ASTM A967; AMS 2700 is strictly a specification on passivation processes. ASTM A967 describes a passivation procedure must follow cleaning and / or descaling. Any contamination not removed prior to passivation reduces a part's corrosion ...
Norme ASTM A967/A967M-17
Normes remplacées (1) ASTM A967/A967M-13. février 2013. Norme Annulée. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning ...
Metals | Free Full-Text | Corrosion Behavior of Passivated
According to ASTM A967, passivation is the chemical treatment of stainless steel with an oxidant agent, to remove free iron or other materials. The passivation baths commonly use citric and nitric acid as oxidizing agents. However, the latter generates toxic vapors that are harmful to health [22,23,24]. On the other hand, citric acid is ...
ASTM-A967 | Standard Specification for Chemical Passivation Treatments
The ASTM A967/A967-13 replaces ASTM A967/A967M-05 which is now obsolete. Keywords. cleaning of stainless steel; passivation; passivation tests; tests for cleanliness of stainless steels;; ICS Number Code 77.140.20 (Steels of high quality) To find similar documents by ASTM Volume: 01.03 (Steel--Plate, Sheet, Strip, Wire; Stainless Steel Bar)
ASTM A967-05
1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless steel parts. It includes several alternative tests, with acceptance criteria, for confirmation of effectiveness of such treatments ...
Passivation of Stainless Steel
* ASTM Committee A-1 on Steel, Stainless Steel, and Related Alloys * ASTM Committee on Standards 100 Barr Harbor Drive West Conshohocken, PA 19428 2. Fed. Spec. QQ-P-35C October 28, 1988 Passivation Treatments For Corrosion Resistant Steel * CANCELLED April 4, 1997 * SUPERSEDED by ASTM A 967 - 96 Copper Sulfate test per MIL-STD-753.
Nitric vs Citric Passivation Methods
A summary of the various nitric acid passivation methods per ASTM A967 is provided below: • Nitric 1: 20-25 v% Nitric Acid, 2.5 w% Sodium Dichromate, 120-130F, 20 Mins minimum • Nitric 2: 20-45 v% Nitric Acid, 70-90F, 30 Mins minimum • Nitric 3: 20-25 v% Nitric Acid, 120-140F, 20 Mins minimum
ASTM A967/A967M : Standard Specification for Chemical …
ASTM A967/A967M, 2017 Edition, July 1, 2017 - Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless …
Chemical Passivation Treatments for Stainless Steel Parts
A 967 2 3. Terminology 3.1 Definition of Term Specific to This Standard—It is necessary to define which of the several commonly used definitions of the term passivation will be …